Загрузка...
09:00 - 21:00

single-phase reclosing energy storage

Faulty phase active power characteristics‐based adaptive single‐phase reclosing …

This paper proposes two novel adaptive single-phase auto-reclosing (ASPAR) schemes for shunt reactors-compensated wind power outgoing (WPO) line. After extinction of a fault on a single phase-tripped...


Hardware implementation of a real-time adaptive single-phase …

In order to distinguish permanent single line-to-ground faults from transient faults and prevent reclosing in the case of a permanent fault occurrence, an adaptive …


Communication-Aided High-Speed Adaptive Single-Phase Reclosing …

Abstract. A new communication-aided high-speed single-phase reclosing algorithm is proposed in this paper for transposed transmission lines based on predicted and measured voltage of faulted phase ...


An Adaptive Three-Phase Reclosing Scheme for Wind Farm Single …

But for the three-phase reclosing, it is still necessary to intertrip the renewable energy source, leading to plenty of units break away from power grid. Xie et al. [12], Zhang et al. [13] and ...


Hardware implementation and performance evaluation of the fast adaptive single-phase auto reclosing …

In this study, we introduced a hardware implementation of a fast adaptive single-phase auto reclosing protection scheme based on harmonic content measurements of the open phase terminal voltage. The simulations were performed with RTDS and the opening and reclosing switching was conducted by the distance relay SEL-421.


A novel adaptive auto-reclosing scheme for transmission lines …

New approach to adaptive single pole auto-reclosing of power transmission lines. S. Jamali A. Parham. Engineering. 2010. In this study, a novel digital algorithm is introduced for recognition of arcing (transient) faults and determination of dead time for adaptive auto-reclosing. The algorithm distinguishes between….


Maintaining balanced three‐phase load voltage during single‐phase auto‐reclosing …

Similarly, for any LG fault in A-phase of line 4 (L4), the faulted phase of circuit breaker of bus 4 (CB4) trips and during SPAR all the three-phase loads at buses 5–9 and 18 get unbalanced voltage.Single-phase load voltage (Load A), in buses 10 and 11, becomes zero.), in buses 10 and 11, becomes zero.


DRS Numerical Single-Phase and Three-Phase Reclosing …

As an alternative, please refer to the F60, 850, F650 or 350 relays. The DRS is a multifunction microprocessor recloser system with a set of algorithms to perform distinct recloser single-phase and three-phase programs. The equipment has also incorporated the synchronism check and the voltage check functions.


New Reclosing Technique in Distribution System with Battery Energy Storage …

Request PDF | New Reclosing Technique in Distribution System with Battery Energy Storage System ... BESS as a UPS were discussed, however, this method can be only applied to the single phase loads ...


Variable DC-Link Voltage Regulation of Single-Phase MMC Battery Energy-Storage System for Reducing Additional Charge Throughput …

Battery energy-storage system (BESS) based on the modular multilevel converter (MMC) can flexibly manage the battery packs integrated into submodules, where the battery pack can directly or through a small capacitor connect to the rear-end half-bridge circuit for reducing cost and volume caused by an additional dc–dc converter. But the alternating …


A review of single phase adaptive auto-reclosing schemes for EHV transmission …

Thus, adaptive single-phase auto-reclosing (ASPAR) based on investigating existing electrical signals has fascinated engineers and researchers. An ASPAR blocks CB reclosing onto permanent faults and allows reclosing permission once secondary arc is quenched.


Novel adaptive reclosing scheme using wavelet transform in distribution system with battery energy storage …

In the fourth step, if a transient fault is recognized, the successful single-phase reclosing time is identified by the PCA-SVM and the reclosing command is issued to high voltage circuit breakers ...


Uninterrupted power supply to BESS based microgrid system using adaptive reclosing …

Since these energy storage units are of limited capacity, it has to be used very efficiently. ... [], for adaptive single-phase reclosing of extra high voltage transmission system breaker. In this context, a wavelet-based method is …


Hardware implementation of a real‐time adaptive single‐phase …

DOI: 10.1002/2050-7038.12344 Corpus ID: 213778383 Hardware implementation of a real‐time adaptive single‐phase auto‐reclosure for power transmission lines @article{Jannati2020HardwareIO, title={Hardware implementation of a real‐time adaptive single‐phase auto‐reclosure for power transmission lines}, author={Mohsen Jannati and …


Three-phase Adaptive Auto-Reclosing for Single Outgoing Line of …

At present, most studies on the single-phase reclosing of the renewable energy power plant are ... This paper demonstrates the operation of a 1 MW/2 MWh grid-tied battery energy storage system ...


Adaptive single-phase/three-phase reclosing scheme for …

The absence of shunt reactor causes quick decrease in electromagnetic energy of the line, ... A high-speed adaptive single-phase reclosing technique based on local voltage phasors IEEE Trans Power Deliv, 32 (3) (2017), pp. 1203-1211 View in …


Single‐phase auto‐reclosing mitigation procedure for …

(a) Four-legged reactor, (b) Three-phase system with HSGS in both terminals, (c) Faulty phase during single-phase tripping and HSGS operation 4.2 High-speed grounding switches (HSGS) For short …


Intrinsic Time Decomposition Based Adaptive Reclosing Technique …

The current signal measured at the local end can be processed by the intrinsic time decomposition technique and the energy function of the first intrinsic mode function (IMF) provides accurate information about the fault clearance. By using such an index, adaptive reclosing is possible in a microgrid system.


Unscented-Kalman-filter-based single-phase adaptive reclosing …

Power Energy Syst., 128 (2021), Article 106744, 10.1016/j.ijepes.2020.106744 View PDF View article View in Scopus Google Scholar ... Implementation and performance evaluation of a harmonic filter for use in adaptive single-phase reclosing, in: 2018 Simp X. ...


Research on a New Single-End Fault Location Method for Single-Phase …

A single-end fault location method for single-phase nonmetallic grounding faults of transmission lines in a double terminal system is studied and proposed. F... where U ˙ m i f and U ˙ m i are the measured voltages of phase i at the measuring point m, respectively, after and before the fault; I ˙ m i f and I ˙ m i are the measured currents of phase i at the …


Uninterrupted power supply to BESS based microgrid …

One of the most common practices is using some energy storage System like battery energy storage system (BESS), flywheels, supercapacitors etc. to store the energy when there is a surplus of it and …


Adaptive single-phase auto-reclosing method using power line …

The proposed method deploys power line carrier (PLC) signals for determination of the secondary arc extinction time and releasing the reclosing signals to the circuit breakers. Despite the growing ...


Reclosing scheme using synchronism checking for utilization of …

Single-phase auto-reclosing (SPAR) is used for restoring power supply to clear temporary single-phase to ground fault in medium-voltage distribution systems. A zigzag winding grounding transformer connected at the remotest load bus rebuilds the three-phase voltage during the SPAR dead time.


Reclosing scheme using synchronism checking for utilization of BESS in distribution system | Journal of Modern Power Systems and Clean Energy

This paper proposes a reclosing scheme using synchronism checking for utilization of battery energy storage system (BESS) in a distribution system. The algorithm disconnects the faulty phase and keeps the power supply from the BESS to the healthy phase. Synchronism checking between the main source side and the load side is …


Single-Phase Auto-Reclosing Scheme Using Particle Filter and …

Abstract: Single-phaseauto-reclosing schemes depend on two main characteristics:(i) secondary arc extinction instant (ii) fault type (temporary or …


Research on Residual Flux Density Measurement for Single-Phase Transformer Core Based on Energy …

When a power transformer is reconnected to the grid, if there is a large residual flux in the iron core, significant inrush current may occur and result in reclosing failure. Thus, accurate measurement of residual flux is necessary to avoid the generating of inrush current. This paper proposes a residual flux density measurement method for …


Energies | Free Full-Text | Adaptive Overhead Transmission Lines Auto-Reclosing …

This paper presents a reliable and fast index to detect the instant of arc extinction for adaptive single-pole automatic reclosing (ASPAR). The proposed method is a simple technique for ASPAR on shunt compensated transmission lines using the Hilbert–Huang Transform (HHT). The HHT method is a combination of the empirical …


Comparison between traditional single‐phase auto reclosing and …

The use of single-phase auto reclosing (SPAR) manoeuvre is most suitable for cases of single-phase faults, since during the procedure the remaining phases continue to transmit energy, allowing a flow of around 54% of the total power for single circuit and up to].


A novel approach to adaptive single phase auto-reclosing …

This paper presents a single-phase auto-reclosing study of a 500 kV Vietnamese transmission line. The success of the single-phase auto-reclosing depends on the extinction of the secondary arc.


Controlled single-phase auto-reclosing technique for shunt reactor compensated lines in electrical energy …

A new controlled Single-Phase Auto Reclosing (SPAR) technique for Shunt Reactor Compensated Transmission Line (SRCTL) in electrical energy systems is presented in this paper. The suggested technique uses a Circuit Breaker (CB) with a Controlled Switching Device (CSD) and a Pre-Insertion Resistor (PIR).


A review of single phase adaptive auto-reclosing schemes for EHV transmission …

Statistics shows that transients produced by lightning or momentary links with external objects, have produced more than 80% of faults in overhead lines. Reclosing of circuit breaker (CB) after a pre-defined dead time is very common however reclosing onto permanent faults may damage the power system stability and aggravate severe …


A novel phasor-based adaptive single-phase auto-reclosing …

A novel adaptive single-phase auto-reclosing method is proposed, which utilizes the internal product ratio of mode voltage to accurately determine the fault natures and the secondary arc extinction time of high-voltage transmission lines equipped with shunt reactors. In this paper, the correlation between the sum of the fault phase voltage and the …


What is Auto Reclosing?

An auto recloser is a high-voltage electric switch that closes automatically. It shuts off electric power when there is a problem, such as a short circuit, just like circuit breakers on domestic electric lines. A recloser automatically examines the electrical cable to determine whether it has removed the problem or not, unlike an automatic ...


Novel adaptive reclosing scheme using wavelet transform in distribution system with battery energy storage …

However, the reclosing scheme in [30] cannot be applied to three-phase loads, and the reclosing scheme in [31] were based on fixed dead time. These are the limitations of these studies. This paper proposes a novel adaptive reclosing scheme to overcome these limitations.


Faulty phase active power characteristics‐based adaptive …

This paper proposes two novel adaptive single-phase auto-reclosing (ASPAR) schemes for shunt reactors-compensated wind power outgoing (WPO) line.


An adaptive reclosing scheme for MVDC distribution networks …

The newly proposed reclosing scheme is based on mechanical DCCBs for structural reuse, with an active signal injection branch added. Since the fault current is restrained by the current limiting reactor installed at the outlet of an MMC, quick isolation of faults is not a must. Thus, mechanical DCCBs can find their usage in DC networks [6].