Загрузка...
09:00 - 21:00

energy storage foot walking video

CN202568540U

The energy storage foot can effectively buffer impact from the ground, so that a user feels labor-saving and comfortable during walking. The utility model discloses an energy storage foot, which comprises a front foot plate, a bearing seat and a rear foot wherein the ...


The influence of energy storage and return foot stiffness on walking …

Carbon fiber prosthetic feet have been developed to minimize these asymmetries by utilizing elastic energy storage and return to provide body support, forward propulsion and leg swing initiation. However, how prosthetic foot stiffness influences walking characteristics is not well-understood. The purpose of this study was to identify …


Effectiveness of an innovative hip energy storage walking orthosis for improving paraplegic walking…

Section snippets Inclusion and exclusion criteria The study included participants aged 18–60 years who met the following criteria: a chronic ( > 6 months) complete spinal cord injury at the level of T4–L2; normal passive hip mobility; and at least 3 months of experience using a walking orthosis (other than the HESWO), such as a hip …


Design and performance analysis of human walking induced energy recovery system by means of hydraulic energy conversion and storage …

In this paper, a hydraulic energy recovery system with consideration of storage is designed to harvest energy from human walking motion, based on gait measurement and analysis of walking dynamics. Conversion from mechanical energy induced by foot stepping into hydraulic energy as well as storage under different …


The effects of a controlled energy storage and return prototype prosthetic foot …

Unilateral transtibial amputees wore the Controlled Energy Storage and Return prosthetic foot (CESR), a conventional foot (CONV), and their previously prescribed foot (PRES) in random order. Three-dimensional gait analysis and net oxygen consumption were collected as participants walked at constant speed.


The influence of energy storage and return foot stiffness on walking …

The influence of energy storage and return foot stiffness on walking mechanics and muscle activity in below-knee amputees Nicholas P. Fey a, Glenn K. Klute b, Richard R. Neptune a,⁎ a Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA ...


Transtibial amputee gait efficiency: Energy storage and return versus solid ankle cushioned heel prosthetic feet

Energy storage and return (ESR) feet have long been assumed to promote metabolically efficient amputee gait. However, despite being prescribed for approximately 30 yr, there is limited evidence that they achieve this desired function. Here, we report a meta-analysis of data from 10 studies that met …


Energy storage and stress-strain characteristics of a prosthetic foot…

This work proposes an experimentally validated numerical approach for a systematic a priori evaluation of the energy storage and stress-strain characteristics of a prosthetic foot ...


The energetic behaviour of the human foot across a range of …

Previous experiments have focussed on the contribution of the PF to energy storage and return within the foot 3,5 ... Sawicki, G. S. Reducing the energy cost of human walking using an unpowered ...


Reducing the energy cost of human walking using an unpowered …

Unlike muscles, however, the clutch sustains force passively. The exoskeleton consumes no chemical or electrical energy and delivers no net positive mechanical work, yet reduces the metabolic cost of walking by 7.2 ± 2.6% for healthy human users under natural conditions, comparable to savings with powered devices.


The Foot''s Arch and the Energetics of Human Locomotion

The arch energy storage model was based on the compressive load-energy storage function established by Ker et al ... Y. Energy cost of walking with flat feet. Prosthey Orthot Int 12, 73–76 (1988 ...


The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation …

Three prosthetic feet were fit and optimally aligned for each participant by the same experienced prosthetist in random order: (1) our prototype Controlled Energy Storage and Return prosthetic foot (CESR; 1.4 kg), (2) a conventional prosthetic foot (CONV, Seattle Lightfoot2, size: 27 cm, Seattle Systems, Poulsbo, WA) in the …


Energy storage and release of prosthetic feet, Part 1: …

Energy storage and release of prosthetic feet, Part 1: biomechanical analysis related to user benefits ... normal subject needs about 3.1 to 3.3 J kg-1m-1 and a lower leg amputee needs about 3.4 till 3.6 J kg-1 m-1 of metabolic energy to walk at a speed of 5 km ...


Spring-like Ankle Foot Orthoses reduce the energy cost of walking …

This energy can take over work of the plantarflexors [10] and/or reducing ipsilateral hip or contralateral leg compensations [12,13]. Both extending the knee and support of ankle push-off power ...


Increasing prosthetic foot energy return affects whole-body …

Prosthetic feet are designed to store energy during early stance and then release a portion of that energy during late stance. The usefulness of providing more …


The influence of energy storage and return foot stiffness on walking mechanics and muscle activity …

Section snippets Methods Prosthetic foot stiffness was modified by altering keel and heel geometry (for details, see South et al., 2010) to yield three SLS feet: one that closely matched the nominal stiffness of a widely prescribed carbon fiber foot (Highlander TM, FS 3000, Freedom Innovations, LLC), one that was 50% stiffer than this foot, and …


The effect of prosthetic ankle energy storage and return properties on muscle activity in below-knee amputee walking …

In an effort to improve amputee gait, energy storage and return (ESAR) prosthetic feet have been developed to provide enhanced function by storing and returning mechanical energy through elastic structures. However, the effect of …


Energy storing and return prosthetic feet improve step length …

Background Energy storing and return (ESAR) feet are generally preferred over solid ankle cushioned heel (SACH) feet by people with a lower limb amputation. While ESAR feet have been shown to have only limited effect on gait economy, other functional benefits should account for this preference. A simple biomechanical model suggests that …


Stiffness and energy storage characteristics of energy storage and return prosthetic feet …

Both stiffness 13–17 and energy storage and return 18–20 properties have been shown to have a significant influence on amputee gait. As a result, a number of studies have attempted to quantify prosthetic foot stiffness 21–25 or energy storage properties. 21–28 These studies often make measurements for a few conditions: loading either the …


The influence of energy storage and return foot stiffness on walking …

However, how prosthetic foot stiffness influences walking characteristics is not well-understood. The purpose of this study was to identify the influence of foot stiffness on kinematics, kinetics, muscle activity, prosthetic energy storage and return, and mechanical efficiency during amputee walking.


The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation …

Unilateral transtibial amputees wore the Controlled Energy Storage and Return prosthetic foot (CESR), a conventional foot (CONV), and their previously prescribed foot (PRES) in random order. Three-dimensional gait analysis and net oxygen consumption were collected as participants walked at constant speed.


A passive mechanism for decoupling energy storage and return …

Energy storage and return (ESR) feet are passive prostheses capable of storing elastic energy during midstance and returning it during late stance to help transition the center of …


Spring-like Ankle Foot Orthoses reduce the energy cost of walking …

Carbon-composite Ankle Foot Orthoses (AFOs) can be prescribed to overcome the reduced ankle push-off [7], [8], [9], and to decrease the elevated energy cost of walking [6]. These carbon-composite AFOs hold spring-like properties, which potentially enable the storage of energy at the beginning of the stance phase and the return of this …


The influence of energy storage and return foot stiffness on walking …

Decreasing foot stiffness can increase prosthesis range of motion, mid-stance energy storage and late-stance energy return, but the net contributions to forward propulsion and swing initiation may be limited as additional muscle activity to provide body support becomes necessary.


Increasing prosthetic foot energy return affects whole-body mechanics during walking …

Energy return was greater with the Pro-Flex foot The Pro-Flex foot demonstrated greater energy storage and return than the Vari-Flex foot (Fig. 3).The Pro-Flex foot stored more energy during ...


Energy storing and return prosthetic feet improve step length …

Walking speed in both foot conditions was on average 1.22 ± 0.02 m∙s − 1. Stride length did not differ between condition (1.38 ± 0.06 vs. 1.37 ± 0.07 for ESAR vs. SACH). Push-off power of the prosthetic foot was significantly higher while walking with the …


Developing an Optimized Low-Cost Transtibial Energy Storage and Release Prosthetic Foot …

Afterwards, a design was envisioned where a simple energy storage and release mechanism was implemented to replace ... on biomechanical responses of foot during walking". Clinical Biomechanics ...


CHANGES TO ENERGY STORAGE AND RETURN FOOT STIFFNESS ALTER THE WALKING …

CHANGES TO ENERGY STORAGE AND RETURN FOOT STIFFNESS ALTER THE WALKING MECHANICS OF BELOW-KNEE AMPUTEES 1 Nicholas P. Fey, 2 Glenn K. Klute and 1 Richard R. Neptune


Increasing prosthetic foot energy return affects whole-body mechanics during walking …

Fey NP, Klute GK, Neptune RR. The influence of energy storage and return foot stiffness on walking mechanics and muscle activity in below-knee amputees. Clinical Biomechanics (Bristol, Avon) 2011; 26:1025–1032. doi: 10.1016/j.clinbiomech.2011.06.007. [] []